Diffuse leakage through an 8-month-old Dacron graft after thrombolysis with tissue plasminogen activator

Szeberin, Zoltán and Szabó, Gábor V. and Sótonyi, Péter and Dósa, Edit (2014) Diffuse leakage through an 8-month-old Dacron graft after thrombolysis with tissue plasminogen activator. Journal of Vascular Surgery, 59 (1). p. 245. ISSN 0741-5214, ESSN: 1097-6809

[img] Text
jvs_2014_Szeberin.pdf
Restricted to Registered users only

Download (443kB) | Request a copy

Abstract

A 56-year-old man was admitted to our department with acute critical left leg ischemia. He had undergone multiple arterial reconstructions of the affected leg over the past 2 years. The last reconstruction was a femorotibial composite silver-impregnated Dacron autologous saphenous vein bypass. Digital subtraction angiography (DSA) showed occlusion of the graft; therefore, selective transcatheter thrombolysis with tissue plasminogen activator ([tPA] alteplase) was started. The 10-mg bolus dose was followed by continuous infusion at a rate of 2.0 mg/h.