REAL

Influence of Can Flatness on Heat Dissipation of Aluminium Electrolytic Capacitor

Kovács, László and Gál, László and Fodor, Dénes (2013) Influence of Can Flatness on Heat Dissipation of Aluminium Electrolytic Capacitor. HUNGARIAN JOURNAL OF INDUSTRY AND CHEMISTRY, 41 (1). pp. 41-46. ISSN 0133-0276

[img]
Preview
Text
14.07_Kovacs_u.pdf

Download (3MB) | Preview

Abstract

The lifetime of aluminium electrolytic capacitors highly depends on their core temperature. Heat dissipation in general applications happens by the extended cathode, which is in contact with the inner side of the can. In the case of heat sink applications, the most important heat transfer phenomenon is the heat conduction through the bottom of the aluminium can. The quantity of the dissipated heat is in direct proportion to the size of the heat transfer surface. The more dissipated heat may increase the lifetime of the capacitor. Therefore, the flatness value of the can bottom is critical. This paper presents a flatness measurement method, which can successfully replace the equipment for a more complex and more expensive 3D measurement. It discusses an implementation of a measurement environment, where data acquisition and visualization are automated by a LabVIEW-based software. In addition, this study deals briefly with the influence of production processes on the flatness value of the capacitor produced by leading manufacturers.

Item Type: Article
Uncontrolled Keywords: flatness measurement; graphical programming environment; Heat dissipation; Measurement automation; aluminium electrolytic capacitor
Subjects: T Technology / alkalmazott, műszaki tudományok > T2 Technology (General) / műszaki tudományok általában
T Technology / alkalmazott, műszaki tudományok > TP Chemical technology / vegyipar, vegyészeti technológia
SWORD Depositor: MTMT SWORD
Depositing User: MTMT SWORD
Date Deposited: 17 Jul 2015 08:43
Last Modified: 17 Jul 2015 08:43
URI: http://real.mtak.hu/id/eprint/25434

Actions (login required)

Edit Item Edit Item