Saracco, Ariel and K. Szabó, Botond and Aspelin, Peter and Leifland, Karin and Tánczos, Ervin (2015) Contrast-enhanced ultrasound using real-time contrast harmonic imaging in invasive breast cancer: comparison of enhancement dynamics with three different doses of contrast agent. ACTA RADIOLOGICA, 56 (1). pp. 34-41. ISSN 0284-1851

[img] Text
Acta_Radiol_2015_Saracco_34_41_three_doses_u.pdf
Restricted to Registered users only

Download (270kB) | Request a copy

Abstract

Background: In the last few years new potential applications have been developed for contrast-enhanced ultrasound (CEUS) and the management of breast diseases, but there is still some debate concerning the optimal dose to evaluate breast lesions, especially as a diagnostic tool. Purpose: To compare different CEUS doses of injected contrast agent in order to establish an optimal dose for the diagnosis of invasive breast cancer. Material and Methods: In Group A we compared the bolus dose of 1.2 mL vs. 2.4 mL and in Group B we compared the bolus dose of 2.4 mL vs. 4.8 mL (26 and 25 invasive carcinomas, respectively). CEUS was performed in real-time contrast harmonic imaging (CHI) using a L9-3 MHz probe. All examinations were recorded in a contrast side/side imaging mode loop for 120 s. Wash-in and wash-out patterns of the contrast agent were analyzed with advanced US quantification software and kinetic curves were used for statistical analysis. Results: In Group B (2.4 mL vs. 4.8 mL), more and stronger correlation was found among kinetic parameters (area under the curve, P< 0.00001; lognormal model parameters, mu, P = 0.0007 and sigma, P< 0.0001; mean transit time, P< 0.0001; model-based wash-out ratios, W-21m, P = 0.0002; W-50m, P = 0.0001; time-to-peak, P = 0.005) as compared to Group A (1.2 mL vs. 2.4 mL). Conclusion: The optimal way to evaluate kinetic features of invasive breast tumors using real-time CEUS is with an injection of contrast agent of either 2.4 mL or 4.8 mL.

Item Type: Article
Uncontrolled Keywords: TUMORS; MASSES; Sonography; BENIGN; FOCAL LIVER-LESIONS; kinetic analysis; invasive breast cancer; doses; Contrast-enhanced ultrasound
Subjects: R Medicine / orvostudomány > RZ Other systems of medicine / orvostudomány egyéb területei
SWORD Depositor: MTMT SWORD
Depositing User: MTMT SWORD
Date Deposited: 25 Sep 2017 08:16
Last Modified: 25 Sep 2017 08:16
URI: http://real.mtak.hu/id/eprint/63565

Actions (login required)

Edit Item Edit Item