REAL

Relationship of circulating hyaluronic Acid levels to disease control in asthma and asthmatic pregnancy

Eszes, Noémi and Toldi, Gergely and Bohács, Anikó and Ivancsó, István and Müller, Veronika and Rigó, János and Losonczy, György and Vásárhelyi, Barna and Tamási, Lilla (2014) Relationship of circulating hyaluronic Acid levels to disease control in asthma and asthmatic pregnancy. PLOS ONE, 9 (4). pp. 1-6. ISSN 1932-6203

[img]
Preview
Text
2577909_Plos_2014.pdf
Available under License Creative Commons Attribution.

Download (519kB) | Preview

Abstract

Uncontrolled asthma is a risk factor for pregnancy-related complications. Hyaluronic acid (HA), a potential peripheral blood marker of tissue fibrosis in various diseases, promotes eosinophil survival and plays a role in asthmatic airway inflammation as well as in physiological processes necessary to maintain normal pregnancy; however the level of circulating HA in asthma and asthmatic pregnancy is unknown. We investigated HA levels in asthmatic patients (N = 52; asthmatic pregnant (AP) N = 16; asthmatic non-pregnant (ANP) N = 36) and tested their relationship to asthma control. Serum HA level was lower in AP than in ANP patients (27 [24.7-31.55] vs. 37.4 [30.1-66.55] ng/mL, p = 0.006); the difference attenuated to a trend after its adjustment for patients' age (p = 0.056). HA levels and airway resistance were positively (r = 0.467, p = 0.004), HA levels and Asthma Control Test (ACT) total score inversely (r = -0.437, p = 0.01) associated in ANP patients; these relationships remained significant even after their adjustments for age. The potential value of HA in the determination of asthma control was analyzed using ROC analysis which revealed that HA values discriminate patients with ACT total score >/=20 (controlled patients) and <20 (uncontrolled patients) with a 0.826 efficacy (AUC, 95% CI: 0.69-0.97, p = 0.001) when 37.4 ng/mL is used as cut-off value in ANP group, and with 0.78 efficacy (AUC, 95% CI: 0.65-0.92, p = 0.0009) in the whole asthmatic cohort. In conclusion circulating HA might be a marker of asthma control, as it correlates with airway resistance and has good sensitivity in the detection of impaired asthma control. Decrease of HA level in pregnancy may be the consequence of pregnancy induced immune tolerance.

Item Type: Article
Subjects: R Medicine / orvostudomány > RC Internal medicine / belgyógyászat
R Medicine / orvostudomány > RG Gynecology and obstetrics / nőgyógyászat, szülészet
SWORD Depositor: MTMT SWORD
Depositing User: MTMT SWORD
Date Deposited: 17 Dec 2018 14:51
Last Modified: 17 Dec 2018 14:51
URI: http://real.mtak.hu/id/eprint/88643

Actions (login required)

Edit Item Edit Item