Evaluation of an open access software for calculating glucose variability parameters of a continuous glucose monitoring system applied at pediatric intensive care unit

Marics, Gábor and Lendvai, Zsófia and Lódi, Csaba and Koncz, Levente and Zakariás, Dávid and Schuster, György and Mikos, Borbála and Hermann, Csaba and Szabó, Attila J. and Tóth-Heyn, Péter (2015) Evaluation of an open access software for calculating glucose variability parameters of a continuous glucose monitoring system applied at pediatric intensive care unit. BIOMEDICAL ENGINEERING ONLINE, 14 (1). pp. 1-13. ISSN 1475-925X

[img]
Preview
Text
s12938_015_0035_3_u.pdf

Download (2MB) | Preview

Abstract

BACKGROUND: Continuous Glucose Monitoring (CGM) has become an increasingly investigated tool, especially with regards to monitoring of diabetic and critical care patients. The continuous glucose data allows the calculation of several glucose variability parameters, however, without specific application the interpretation of the results is time-consuming, utilizing extreme efforts. Our aim was to create an open access software [Glycemic Variability Analyzer Program (GVAP)], readily available to calculate the most common parameters of the glucose variability and to test its usability. METHODS: The GVAP was developed in MATLAB(R) 2010b environment. The calculated parameters were the following: average area above/below the target range (Avg. AUC-H/L); Percentage Spent Above/Below the Target Range (PATR/PBTR); Continuous Overall Net Glycemic Action (CONGA); Mean of Daily Differences (MODD); Mean Amplitude of Glycemic Excursions (MAGE). For verification purposes we selected 14 CGM curves of pediatric critical care patients. Medtronic(R) Guardian(R) Real-Time with Enlite(R) sensor was used. The reference values were obtained from Medtronic(R)'s own software for Avg. AUC-H/L and PATR/PBTR, from GlyCulator for MODD and CONGA, and using manual calculation for MAGE. RESULTS: The Pearson and Spearman correlation coefficients were above 0.99 for all parameters. The initial execution took 30 minutes, for further analysis with the Windows(R) Standalone Application approximately 1 minute was needed. CONCLUSIONS: The GVAP is a reliable open access program for analyzing different glycemic variability parameters, hence it could be a useful tool for the study of glycemic control among critically ill patients.

Item Type: Article
Subjects: R Medicine / orvostudomány > RJ Pediatrics / gyermekgyógyászat
SWORD Depositor: MTMT SWORD
Depositing User: MTMT SWORD
Date Deposited: 18 Dec 2018 09:04
Last Modified: 18 Dec 2018 09:04
URI: http://real.mtak.hu/id/eprint/88648

Actions (login required)

Edit Item Edit Item