REAL

Stable laser-Doppler flow-motion patterns in the human cutaneous microcirculation

Tóth-Szűki, Valéria and Bari, Ferenc and Domoki, Ferenc (2020) Stable laser-Doppler flow-motion patterns in the human cutaneous microcirculation. Physiology International, 107 (1). pp. 134-144. ISSN 2498-602X

[img]
Preview
Text
article-p134.pdf

Download (791kB) | Preview

Abstract

Microvascular function has been assessed by determining the rhythmic oscillations in blood flow induced by the vasomotion of resistance vessels. Although laser-Doppler flowmetry (LDF) allows simple, non-invasive evaluation of this flow-motion in the cutaneous microcirculation, the temporal and spatial reproducibility of such assessments remains unclear.In the present study, we investigated cutaneous flow-motion in three consecutive years in eight skin regions using LDF in six healthy young volunteers. The characteristic flow-motion frequency was determined using fast-Fourier transformation. Additionally, in two years a more traditional measure of microvascular reactivity, postocclusive reactive hyperemia (PORH) was evoked in the forearm after transient brachial artery occlusion (1-2-3 min) induced by cuff inflation.Well-defined flow-motion was found in six regions showing significant differences in frequency: the highest flow-motion frequency was found in the frontal and temporal regions (8.0 ± 1.1 and 8.5 ± 1.0 cycles/min, cpm, respectively, mean ± SD) followed by the scapular, infraclavicular and coxal regions (7.5 ± 1.3; 6.7 ± 1.1 and 6.5 ± 1.2 cpm, respectively). The lowest, stable flow-motion was found in the posterior femoral region (5.5 ± 1.0 cpm), whereas flow-motion was detectable only sporadically in the limbs. The region-dependent flow-motion frequencies were very stable within individuals either between the body sides, or among the three measurements, only the infraclavicular region showed a small difference (114 ± 17%∗, % of value in 1st year; ∗P < 0.05). However, PORH indices differed after 2-3 min occlusions significantly in consecutive years.We report that flow-motion frequencies determined from LDF signals show both region-specificity and excellent intra-individual temporal and spatial reproducibility suggesting their usefulness for non-invasive follow-up of microvascular reactivity.

Item Type: Article
Uncontrolled Keywords: Laser-Doppler Flowmetry; postocclusive hyperemia; vasomotion; cutaneous blood flow; microvascular reactivity;
Subjects: R Medicine / orvostudomány > R1 Medicine (General) / orvostudomány általában
SWORD Depositor: MTMT SWORD
Depositing User: MTMT SWORD
Date Deposited: 12 Aug 2021 12:05
Last Modified: 12 Aug 2021 12:05
URI: http://real.mtak.hu/id/eprint/128405