Wagnerová, Emília and Imriš, Ivan (2001) Air flow through an ejector with annular supersonic nozzle. JOURNAL OF COMPUTATIONAL AND APPLIED MECHANICS, 2 (1). pp. 157-160. ISSN 1586-2070
|
Text
2-1-EmiliaWAGNEROVA-V2N1.pdf - Published Version Download (729kB) | Preview |
Official URL: http://jcam.uni-miskolc.hu
Abstract
During development of the continuous production of copper dried concentrate and fluxes were injected through the top-blowing lance into the molten bath. The properties of the equipment designed were determined by both classical measurements and modern flow visualization methods. The results of the classical measurements of the air flow parameters through an ejector with annular supersonic nozzle were confirmed by the Shleer and the shade methods of flow visualization.
| Item Type: | Article |
|---|---|
| Uncontrolled Keywords: | ejector, annular nozzle, supersonic flow, copper |
| Subjects: | T Technology / alkalmazott, műszaki tudományok > T2 Technology (General) / műszaki tudományok általában |