Accuracy of ultrasonic flow-meters on short straight sections of water pipelines

Bosak, Mykola and Matlai, Ivan and Popadiuk, Ihor (2025) Accuracy of ultrasonic flow-meters on short straight sections of water pipelines. POLLACK PERIODICA: AN INTERNATIONAL JOURNAL FOR ENGINEERING AND INFORMATION SCIENCES, 20 (2). pp. 86-93. ISSN 1788-1994

[img] Text
606-article-p86.pdf - Published Version
Restricted to Repository staff only

Download (969kB)

Abstract

This paper presents experimental results using the ultrasonic flow-meter “Dnipro-7U” on limited straight sections of water pipelines located before turns and branches. In these pipeline sections, asymmetric water velocity profiles can lead to reduced accuracy in flow measurements using an ultrasonic flow-meter.

Item Type: Article
Uncontrolled Keywords: ultrasonic flow-meter; water flow rate; flow velocity; velocity profile; pipeline section; hydraulic resistance