Posta, Bálint and Nagy, Roland and Perényi, Ádám and Csanády, Miklós and Jarabin, János András and Ivaskó, Lívia and Molnár, Fiona Anna and Perényi-Csáthi, Éva Ibolya and Bere, Zsófia and Rovó, László (2026) Újgenerációs „okos” cochlearis implantátum (Cochlear™ Nucleus® Nexa™) magyarországi bevezetése és korai tapasztalataink = Introduction of a next-generation "smart" cochlear implant (Cochlear™ Nucleus® Nexa™) in Hungary: our early experiences. ORVOSI HETILAP, 167 (44). pp. 1778-1784. ISSN 0030-6002
|
Text
650-article-p1778.pdf - Published Version Available under License Creative Commons Attribution. Download (2MB) | Preview |
Abstract
Bevezetés: A Szegedi Tudományegyetem Szent-Györgyi Albert Orvostudományi Karának Fül-Orr-Gégészeti és FejNyaksebészeti Klinikáján 1995-ben került sor az első cochlearis implantációra, azóta intézetünkben összesen 1077 beültetés történt. 2025. június 25–26-án klinikánkon elvégeztük a Cochlear™ Nucleus® Nexa™ rendszer első magyarországi implantációit, amely a gyártó által a világ első „okos” cochlearis implantátumaként bemutatott terméke. Célkitűzés: Munkacsoportunk célja a hazai Nexa™ -beültetések korai tapasztalatainak összefoglalása, amelyek a korszerű cochlearis implantációs technológia új mérföldkövét jelenthetik. Módszer: Két, sensorineuralis halláscsökkenéssel élő beteg – egy 11 éves gyermek és egy 56 éves nő – bal oldali cochlearis implantációját végeztük el az új implantátumrendszerrel. A műtéteket standard transmastoid behatolásból, posterior tympanotomiát követően, kerekablak-feltárással hajtottuk végre. Ellenőrzésként intraoperatív elektrofiziológiai méréseket – impedanciavizsgálatot, transzimpedanciamátrix-vizsgálatot, az elektromosan kiváltott stapediusreflex küszöbértékének vizsgálatát és idegiválasz-telemetriát – alkalmaztunk. Eredmények: Mindkét műtét szövődménymentesen zajlott. Az intraoperatív mérések megfelelő implantátumműködést igazoltak, a posztoperatív szak eseménytelen volt. A külső beszédprocesszor első aktiválása és illesztése a korábban alkalmazott rendszerekhez hasonló munkafolyamat szerint, az implantált elektronika programozásával kiegészítve történt. Az első beállítás és az illesztés mindkét esetben problémamentesen zajlott, a korai audiológiai tapasztalatok pedig kedvezőek voltak. Megbeszélés: A Nexa™ rendszer újdonságát a belső egység jövőbeli frissíthetősége, az implantátum szintjén megvalósuló adatkezelés, valamint az intraoperatív ellenőrzést és a hosszú távú gondozást támogató új technológiai megoldások adják. Első tapasztalataink alapján az implantátumrendszer a megszokott sebészi és audiológiai munkafolyamatokba biztonságosan beilleszthető. Következtetés: A Nexa™ rendszer első magyarországi alkalmazása fontos technológiai előrelépést jelenthet a hazai cochlearis implantációs ellátásban. Az új technológia lehetőséget biztosít a jövőbeli fejlesztésekhez. Orv Hetil. 2026; 167(44): 1778–1784. | The first cochlear implantation at the Department of Oto-Rhino-Laryngology and Head and Neck Surgery, Albert Szent-Györgyi Medical School, University of Szeged, was performed in 1995. Since then, 1077 implantations have been carried out at our institution. On 25-26 June 2025, we performed the first Hungarian implantations of the Cochlear™ Nucleus® Nexa™ system at our department. The manufacturer presents this device as the world's first "smart" cochlear implant.The aim of our study was to summarize the early experience with Nexa™ implantations in Hungary, which may represent a new milestone in modern cochlear implant technology.Two patients with sensorineural hearing loss - an 11-year-old child and a 56-year-old woman - underwent left-sided cochlear implantation with the new implant system. Both procedures were performed through a standard transmastoid approach, followed by posterior tympanotomy and round-window access. Intraoperative electrophysiological measurements, including impedance testing, transimpedance matrix measurement, electrically evoked stapedius reflex threshold measurement and neural response telemetry, were used for device and electrode function assessment.Both operations were completed without complications. Intraoperative measurements confirmed appropriate implant function, and the postoperative course was uneventful in both patients. Initial activation and fitting of the external sound processor followed a workflow similar to that used with previous systems, supplemented by programming of the implanted electronics. Initial programming and fitting were completed without technical difficulties in both cases, and the early audiological experience was favorable.The novelty of the Nexa™ system lies in the future upgradeability of the internal unit, implant-level data management, and new technological solutions supporting intraoperative monitoring and long-term care. Based on our initial experience, the implant system can be safely integrated into established surgical and audiological workflows.The first Hungarian use of the Nexa™ system may represent an important technological advance in cochlear implant care in Hungary. Its upgradeable architecture may allow recipients to benefit from future technological developments. Orv Hetil. 2026; 167(44): 1778-1784.
| Item Type: | Article |
|---|---|
| Additional Information: | Journal Article; Case Reports; English Abstract |
| Uncontrolled Keywords: | Sensorineural hearing loss; cochlear implantation; cochlearis implantáció; hallásrehabilitáció; hearing rehabilitation; sensorineuralis halláscsökkenés; “smart” implant; „okos” implantátum; |
| Subjects: | R Medicine / orvostudomány > R1 Medicine (General) / orvostudomány általában |
| SWORD Depositor: | MTMT SWORD |
| Depositing User: | MTMT SWORD |
| Date Deposited: | 12 Nov 2026 15:00 |
| Last Modified: | 12 Nov 2026 15:00 |
| URI: | https://real.mtak.hu/id/eprint/250099 |
Actions (login required)
![]() |
View Item |