REAL

Inspection of Local Wall Thinning by Different Magnetic Methods

Vértesy, G. and Gasparics, A. and Tomas, I. (2018) Inspection of Local Wall Thinning by Different Magnetic Methods. JOURNAL OF NONDESTRUCTIVE EVALUATION, 37 (3). pp. 1-8. ISSN 0195-9298

[img] Text
Vertesy2018_Article_InspectionOfLocalWallThinningB_u.pdf
Restricted to Repository staff only

Download (3MB)

Abstract

The applicability of three different magnetic methods, Magnetic flux leakage technique (MFL), Magnetic adaptive testing and Metal memory method (MMM) was tested for detection of an artificial slot in a system of three steel plates. It was found that MAT resulted in the best signal/noise ratio, and it is capable to detect the bottom side slot even in the three layer configuration. MFL also resulted in acceptable signal/noise ratio in the two layer configuration, but it was not able to detect the slot through two other plates. MMM was not found to be suitable for unstressed and un-magnetized slot detection in the given experimental arrangement.

Item Type: Article
Subjects: Q Science / természettudomány > QC Physics / fizika > QC04 Electricity. Magnetism. Electromagnetism / villamosság, mágnesesség, elektromágnessesség
SWORD Depositor: MTMT SWORD
Depositing User: MTMT SWORD
Date Deposited: 28 Aug 2018 07:46
Last Modified: 28 Aug 2018 07:46
URI: http://real.mtak.hu/id/eprint/83024

Actions (login required)

Edit Item Edit Item