REAL

The effect of high-irradiance rapid polymerization on degree of conversion, monomer elution, volumetric change and porosity of bulk-fill resin composites

Lempel, Edina and Szebeni, D. and Őri, Zsuzsanna Emese and Kiss, T. and Szalma, József and Lovász, Bálint Viktor and Kunsági-Máté, Sándor and Böddi, Katalin (2023) The effect of high-irradiance rapid polymerization on degree of conversion, monomer elution, volumetric change and porosity of bulk-fill resin composites. DENTAL MATERIALS, 39 (4). pp. 442-453. ISSN 0109-5641

[img]
Preview
Text
DENTMA-S-22-00830-2.pdf

Download (4MB) | Preview

Abstract

The purpose was to compare the degree of conversion (DC), monomer elution (ME), polymerization shrinkage (PS) and porosity of two addition-fragmentation chain transfer (AFCT) modified resin-based composites (RBC) light-cured with rapid- (RP), turbo- (TP) or conventional polymerization (CP) settings.Cylindrical samples (6-mm wide, 4-mm thick) were prepared from Tetric PowerFill (TPF) and Filtek One Bulk (FOB). Four groups were established according to the polymerization settings: 3s-RP, 5s-TP, 10s-CP and 20s-CP. Samples in 1 mm thickness with 20s-CP settings served as controls. The DC at the top and bottom surfaces was measured with micro-Raman spectroscopy. ME was detected with high-performance liquid chromatography. PS and porosity were analyzed by micro-computed tomography. ANOVA and Tukey's post-hoc test, multivariate analysis and partial eta-squared statistics were used to analyze the data (p < 0.05).FOB showed higher DC values (61.5-77.5 %) at the top compared to TPF (43.5-67.8 %). At the bottom TPF samples achieved higher DCs (39.9-58.5 %) than FOB (18.21-66.18 %). Extending the curing time increased DC (except the top of FOB) and decreased ME. BisGMA release was the highest among the detected monomers from both RBCs. The amount was three-fold more from TPF. The factor Material and Exposure significantly influenced DC and ME. PS (1.8-2.5 %) did not differ among the groups and RBCs except for the lowest value of TPF cured with the 3s_RP setting (p = 0.03). FOB showed 4.5-fold lower porosity (p < 0.001). Significantly higher pore volume was detected after polymerization in 3s_RP (p < 0.001).High-irradiance rapid 3-s curing of AFCT modified RBCs resulted in inferior results for some important material properties. A longer exposure time is recommended in a clinical situation.

Item Type: Article
Subjects: Q Science / természettudomány > QD Chemistry / kémia > QD02 Physical chemistry / fizikai kémia
Q Science / természettudomány > QD Chemistry / kémia > QD04 Organic chemistry / szerves kémia
R Medicine / orvostudomány > RK Dentistry / fogászat
SWORD Depositor: MTMT SWORD
Depositing User: MTMT SWORD
Date Deposited: 04 Sep 2023 07:55
Last Modified: 04 Sep 2023 07:55
URI: http://real.mtak.hu/id/eprint/172508

Actions (login required)

Edit Item Edit Item