Kutyifa, Valentina and Zima, Endre István and Molnár, Levente Domonkos and Kuehne, C. and Theiss, S. and Gellér, László Alajos and Merkely, Béla Péter (2013) Direct comparison of steroid and non-steroid eluting small surface pacing leads: Randomized, multicenter clinical trial. CARDIOLOGY JOURNAL, 20 (4). pp. 431-438. ISSN 1897-5593
|
Text
direct_compar_kutyifa_u.pdf Download (128kB) | Preview |
Abstract
BACKGROUND: The aim of the study was to evaluate the effi cacy and safety of small surface steroid-eluting atrial and ventricular pacing leads in comparison to non-steroid leads using remote monitoring system (Biotronik Home Monitoring(R)). METHODS: In this randomized multicenter prospective trial, SIELLO T steroid-eluting ventricular leads (n = 42) were compared to BPPU T non-steroid leads (n = 46) and SIELLO JT steroid-eluting atrial leads (n = 24) to BPPU JT non-steroid leads (n = 27) (Biotronik, Berlin, Germany) in pacemaker devices with remote monitoring capabilities. Lead parameters were evaluated during implantation, at 1-week and 1, 3, 6-month outpatient follow-up. Remote monitoring data were collected weekly. RESULTS: Atrial and ventricular steroid-eluting leads had stable sensing and impedance as compared to non-steroid leads at implantation and during follow-up. Patients with non-steroid atrial leads had signifi cantly higher threshold compared to steroid leads at 1-week and at 1, 3, 6-month follow-up with a peak at 1-month (1-month 1.4 +/- 0.6 vs. 0.7 +/- 0.3 V at 0.4 ms, p < 0.001; 6-month 0.3 +/- 0.5 vs. 0.2 +/- 0.3 V at 0.4 ms, p = 0.002). Patients with non-steroid ventricular leads had signifi cantly higher threshold compared to steroid leads at 1, 3, 6-month (6-month 1.0 +/- 0.3 vs. 0.6 +/- 0.2 V at 0.4 ms, p < 0.001). Remote monitoring confi rmed consistent results. During the study, 3 patients died of non-lead-related death. Lead repositioning was necessary in 2 atrial, 2 ventricular steroid leads and in 1 ventricular non-steroid lead. CONCLUSIONS: Atrial and ventricular pacemaker leads with steroid showed signifi cantly lower pacing threshold compared to non-steroid leads, confi rmed by remote monitoring.
Item Type: | Article |
---|---|
Subjects: | R Medicine / orvostudomány > RZ Other systems of medicine / orvostudomány egyéb területei |
SWORD Depositor: | MTMT SWORD |
Depositing User: | MTMT SWORD |
Date Deposited: | 26 Sep 2015 09:30 |
Last Modified: | 26 Sep 2015 09:30 |
URI: | http://real.mtak.hu/id/eprint/28206 |
Actions (login required)
![]() |
Edit Item |