Evaluation of possibilities in identification and susceptibility testing for Candida glabrata clinical isolates with the Integral System Yeast Plus (ISYP)

Szweda, Piotr and Gucwa, Katarzyna and Naumiuk, Lukasz and Romanowska, Ewa and Dzierzanowska-Fangrat, Katarzyna and Brillowska-Dabrowska, Anna and Wojciechowska-Koszko, Iwona and Milewski, Slawomir (2014) Evaluation of possibilities in identification and susceptibility testing for Candida glabrata clinical isolates with the Integral System Yeast Plus (ISYP). Acta Microbiologica et Immunologica Hungarica, 61 (2). pp. 161-172. ISSN 1217-8950

[img] Text
amicr.61.2014.2.6.pdf
Restricted to Repository staff only until 30 June 2034.

Download (77kB)

Abstract

The aim of this study was to evaluate possibilities of correct identification and susceptibility testing of C. glabrata clinical isolates with Integral System Yeast Plus (ISYP). For species identification, as the reference method, API Candida test and species-specific PCR reactions were used. The potential of antifungal susceptibility testing by the ISYP test was compared with the Sensititre Yeast One. Whilst the reference methods confirmed that the received population (n = 65 isolates) represented only C. glabrata, identification with the ISYP system showed correct data only in the case of 18 strains tested (27.7%). Species identification of the other 47 strains with the ISYP test was not possible at all. Significant differences were also observed for drug susceptibility testing carried out by the ISYP and the Sensititre Yeast One. The highest level of disagreement in classifying strains as resistant or susceptible estimated, as 73.9% and 40.0%, was observed for itraconazole and amphotericin B, respectively. Satisfactory results were only obtained for 5-fluorocytosine with 93.8% agreement between both methods. In our opinion the idea of the ISYP system is certainly good. The combination of identification ability and drug susceptibility testing in one test is very important, especially from a clinical point of view. However, the current version of the ISYP has many disadvantages. We would like to encourage the manufacturer to make an effort and develop a new, more accurate version of the test.

Item Type: Article
Subjects: Q Science / természettudomány > QR Microbiology / mikrobiológia
Depositing User: Ágnes Sallai
Date Deposited: 28 Mar 2017 07:43
Last Modified: 28 Mar 2017 07:43
URI: http://real.mtak.hu/id/eprint/50578

Actions (login required)

Edit Item Edit Item