Nádházi, Z. and Takáts, A. and Offenmüller, K. and Bertók, L. (2002) Plasma endotoxin level of healthy donors. Acta Microbiologica et Immunologica Hungarica, 49 (1). pp. 151-157. ISSN 1217-8950

[img]
Preview
Text
amicr.49.2002.1.15.pdf

Download (97kB) | Preview

Abstract

The plasma level of endotoxin was determined in 116 healthy blood donors. After a routine physical and laboratory investigations the endotoxin level was determined with Limulus amebocyte lysate assay (LAL-test) by the chromogenic kinetic method of Bio-Whittaker Co. (USA). Its sensitivity was 0.005-50 EU/ml. The plasma level of endotoxin in most of the healthy donors was less than 1 EU/ml (in the range of 0.01-1.0 EU/ml), but always measurable. The average ±S.D. was 0.128±0.215 EU/ml. Because of the high standard deviation and high range of values, the data were distributed into two groups with the means of 0.05±0.022 EU/ml and 0.294±0.186 EU/ml. The difference between the groups was significant (p<0.001). In conclusion, endotoxin can be measured in plasma of healthy individuals.