Dimák, Balázs and Schulcz, Rebeka and Nagy, Roland and Bere, Zsófia and Posta, Bálint and Perényi, Ádám and Rovó, László and Csanády, Miklós (2024) Korai tapasztalatok az Advanced Bionics cochlearis implantátummal = Early experiences with the Advanced Bionics cochlear implant. ORVOSI HETILAP, 165 (45). pp. 1772-1778. ISSN 0030-6002
|
Text
650-article-p1772.pdf - Published Version Available under License Creative Commons Attribution. Download (564kB) | Preview |
Abstract
Bevezetés: A Szegedi Tudományegyetem Szent-Györgyi Albert Orvostudományi Karának Fül-Orr-Gégészeti és Fej-Nyaksebészeti Klinikáján 1995-ben történt az első cochlearis implantáció. 2022. augusztus 11-én lehetőség nyílt klinikánkon a hazánkban még kevésbé ismert, de nemzetközileg elismert implantátumgyártó cég, az Advanced Bionics által forgalmazott HiRes Ultra 3D implantátum beültetésére. Célkitűzés: Klinikánkon jelenleg a páciensek a Cochlear Ltd., illetve a MED-EL GmbH készülékeivel kerülnek rehabilitációra. Ezen ellátási spektrum kiszélesítése érdekében megtörtént az első Advanced Bionics cochlearis implantációs műtét klinikánkon. A jelen tanulmány célja e tapasztalatok ismertetése. Módszer: Tanulmányunk során beültetésre került egy HiRes Ultra 3D implantátum. Az operáció alatt elektrofiziológiai mérések (elektromosan kiváltott stapediusreflex-küszöb [ESRT], idegiválasz-telemetria [NRT] és impediancia) történtek. Eredményeinket az Active Insertion Monitoring rendszer segítségével rögzítettük. Eredmények: Az impedanciaértékek megfelelőek voltak, az idegi válasz és az elektromos stapediusreflex kiváltható volt. A klinikai protokoll értelmében a közvetlen sebzárás után az elektróda cochleán belüli pozícióját kis dózisú fluoroszkópos felvétellel is ellenőriztük. Megbeszélés: Rövid távú tapasztalataink azt mutatják, hogy az Advanced Bionics implantátum teljes mértékben alkalmas a belsőfül-eredetű irreverzibilis halláskárosodás kezelésére. Következtetés: Eredményeink alapján az implantátum lehetőséget nyújt a hallásmaradvány megőrzésére is. Műtéttechnikai szempontból hasonló konstrukciót kínál, mint a jelenlegi klinikai portfólióban szereplő másik két gyártó készülékei. | Introduction: The first cochlear implantation was performed in 1995 at the Department of Otorhinolaryngology and Head and Neck Surgery of the Albert Szent-Györgyi Medical School at the University of Szeged. On August 11, 2022, our clinic had the opportunity to insert the HiRes Ultra 3D implant, distributed by Advanced Bionics, a company that is less known in Hungary but internationally well-recognized. Objective: Currently, patients at our clinic are rehabilitated with devices from Cochlear Ltd. and MED-EL GmbH. To broaden this range of services, the first Advanced Bionics cochlear implantation surgery was performed at our clinic. Method: In our study, a HiRes Ultra 3D implant was implanted. During the operation, electrophysiological measurements (electrically evoked stapedius reflex threshold [ESRT], neural response telemetry [NRT], and impedance) were performed. The results were recorded using the Active Insertion Monitoring system. Hereinafter, we would like to review our initial experience. Results: The impedance thresholds were adequate, and both the neural response and the electrical stapedius reflex were responsible included . In accordance with the clinical protocol, after the immediate wound closure, the position of the electrode within the cochlea was also checked with low-dose fluoroscopic imaging. Discussion: Our short-term experience indicates that Advanced Bionics implant is fully suitable for serve sensorineural hearing loss. Conclusion: Based on our results, the implant offers the possibility of preserving residual hearing. From a surgical technique perspective, it provides a construction similar to the other two manufacturers’ current devices in the clinical portfolio.
Item Type: | Article |
---|---|
Uncontrolled Keywords: | cochlearis implantáció, halláscsökkenés, hallásmaradvány megőrzése, cochlear implantation, hearing loss, hearing preservation |
Subjects: | R Medicine / orvostudomány > RF Otorhinolaryngology / orr-, fül-, gégészet |
SWORD Depositor: | MTMT SWORD |
Depositing User: | MTMT SWORD |
Date Deposited: | 18 Nov 2024 13:45 |
Last Modified: | 18 Nov 2024 13:45 |
URI: | https://real.mtak.hu/id/eprint/209929 |
Actions (login required)
Edit Item |