Abstract

OLMOST-HT project aimed to develop an integrated hardware and software system for on-line and on-site measurement of structure displacements in most critical regions in order to prevent failure due to flaw or fatigue occurred by degradation mechanism as creep, thermal ageing, and hydrogen embitterment on high temperature. Due to the unknown condition and the high consequences of any failure means that the operational risk can be extraordinary high. To prevent failure, maintenance in time requires special dedicated monitoring techniques. Having proper online global and local displacement and deformation data comparison can be done between the estimated and real data and decision can be. In this paper the previous experience of the OLMOST-HT monitoring system is presented. This study describes the main laboratory test, the trial of the monitoring system and a finite element case study of a catalytic reactor.

Item Type: Article
Subjects: Q Science / természettudomány > QA Mathematics / matematika > QA76.76 Software Design and Development / Szoftvertervezés és -fejlesztés
T Technology / alkalmazott, műszaki tudományok > TJ Mechanical engineering and machinery / gépészmérnöki tudományok
SWORD Depositor: MTMT SWORD
Depositing User: MTMT SWORD
Date Deposited: 10 Nov 2026 18:13
Last Modified: 10 Nov 2026 18:13
URI: https://real.mtak.hu/id/eprint/249855

Actions (login required)

View Item View Item